2.2 COMPONENTS ELUCIDATION
- indicated for information about the Button operation.
Button
DATA-H
Any switch position
Power-up Option
V
RANGE
MAX.H
Any switch position
Button
FUNC.
- Transform Switch
This switch is used to select functions and desired ranges.
- Probe
Input terminals for V、mA、Ω/
- COM Jack
Common terminal for measurement.
- LCD Display
The measuring result will be displayed.
- LED Indicator
At Logic test range, High level and Low level can be indicated.
- Rotatable Probe Socket
Rotating the probe in or out of the meter.
- Protection Ring
To keep the hand from the probe behind the ring.
3. SPECIFICATIONS
Accuracy is specified for a period of year after calibration and at 18℃ to 28℃(64℉ to 82℉)with relative humidity to 75%.

3.1 GENERAL SPECIFICATIONS

3.1.1 Environment conditions:
600V CAT. III
Pollution degree: 2
Altitude < 2000m
Operating temperature: 0~40℃, 32℉~122℉(<80% RH, <10 non-condensing)
Storage temperature: -10~50 ℃, 14℉~122℉(<70% RH, battery removed)
3.1.2 Max. Voltage Between Terminals And Earth Ground: 600V DC or AC
3.1.3 Auto ranges and manual range.
3.1.4 Display: 20mm LCD
3.1.5 Max. Show Value: 1999 (3 1/2)
3.1.6 Polarity Indication: '-'indicates negative polarity.
3.1.7 Overrange Indication: Display 'OL'.
3.1.8 Sampling Time: approx. 0.4 second
3.1.9 Unit showing: showing of function and electrical capacity.
3.1.10 Low Battery Indication: '
3.1.11 Fuse Protection: mA: resettable fuse
3.1.12 Auto power off time: 15 min.
3.1.13 Power Supply: 1.5V×2 AAA battery.
3.1.14 Dimension: 208×38×29 mm
3.1.15 Weight: approx. 110g(including battery)
Customer Care Australia P: 133 122 F: 1300 303 310 E: [email protected] W: cabac.com.au
A: 8 Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected] W: cabac.co.nz
Function
This Button is used to hold data.
Disables automatic power-off feature.
, Ω and mA
Used to transform Auto range or manual range.
Used to measure and hold the maximum value.
Function
V
Switches between dc and ac voltage.
Keep pressing during the Logic testing.
Logic
Switches between Resistance measurement, Diode Test and Continuity check.
Ω
Switches between dc and ac current.
mA
/
and logic test.
' displayed
Operation performed
Operation performed