Argal TMR 06.10 Handleiding gebruiken - Pagina 2
Blader online of download pdf Handleiding gebruiken voor {categorie_naam} Argal TMR 06.10. Argal TMR 06.10 20 pagina's.
2
DISASSEMBLING SEQUENCE
TOOLS
Spanner No 13
EXECUTION NOTES
To
facilitate
the
pump
operations, first disassembly the HYDRAULIC
PARTS from the MOTOR PARTS
unscrew the connections (POS.1)
warning! The disassembly operations of parts
magnetically connected involve great opposed
forces: keep the MOTOR PARTS fixed on
floor during the removing of the HYDRAULIC
PARTS.
HYDRAULIC PARTS
1
Pos. Ref. Part name
910.1 Connection volute casing/strainer
1
MANUALE D'USO ROUTE - rev. 2 - 10/01
WARNING
The interventions must be performed under supervision of qualified personnel.
Before starting remember:
cut off the power supply from the motor and disconnect the electrical wiring; pull the
wires out from the terminal box and isolate their extremities accordingly
close the suction and discharge valves; open the drain valve
use appropriate gloves, protective glosses and acid proof-clothing when
disconnecting and washing the pump
disconnect hydraulic connections: leave enough time for the residual liquid to exit the
pump casing and atmosferic air to fill the empty volume
wash the pump before starting maintenace operations
do not scatter the washing liquid in the environment
disassembling
before attempting to dismantle the pump ensure that its motor is disconnected and
that it may not be started accidentally
before the inspection, check that you have spare O-rings ready to hand for re-
installing at the end of operations
warning! Operations near the magnets attract the tools. Proceed with caution to
avoid damages.
DISASSEMBLING STEPS SEQUENCE
MOTOR PARTS
Fig. 2.A – disassembling steps sequence
For further details see paragraph 9.1 "Disassembling"
Q.ty
Disassembling steps sequence
No
1
2
3
4
5
3
•
Spare stock for
working years
6
7
8
9
10
2
pag. 2/15
5