Basic Installation

1. Verify all components included are present before installation.
2. Connect an HDMI source device to the HDMI IN port using an HDMI cable
3. Connect a display device to the HDMI OUT port using an HDMI cable. If using CEC on and off support, make
sure the CEC option on your display has been enabled in the displays settings menu.
4. Adjust EDID preset for desired resolution setting
5. Connect either S/PDIF OUT or AUDIO OUT to an audio amplifier or AVR for audio reinforcement with an RCA
or 3.5mm audio .cable
6. If using a projector screen or window shade, connect RELAY1 / RELAY2 to the relay pins of a relay switch
on a projector screen or window shade with a shielded 2 conductor cable with a ground, such as the
Liberty 22-1P-EZ cable
• RELAY1 will automatically switch from normally open (NO) to normally closed (NC) when a video signal is introduced to the system.
RELAY2 will automatically switch from normally open (NO) to normally closed (NC) when a video signal is absent from system after a
specified time that has been determined by the serial upload software. Default system timeout is set to 3 minutes and default relay
mode is set to latching.
7. (Optional if not using CEC Display Control) Connect the 3 pin phoenix connector of the RS232 breakout cable to
the RS232 port on the DL-UHDILC, then connect the DB-9 side of the breakout cable to a DB9 cable to connect
that will connect to the sink device
• NOTE: The RS232 port on the DigitaLinx DL-UHDILC must be configured by connecting a computer to the RS232 port of the DL-
UHDILC and by using the DL-UHDILC Configuration Software which is located on the DL-UHDILC product page Online at www.libav.
com.
8. Apply power to DL-UHDILC

RS232 Connections

To use the pre-loaded RS232 control port to tripper on and off commands to a display or projector, connect the
TX, RX, and ground control signal wires to the middle RS232 connections on the removable 6-pole terminal block.
Consult the manual of the display or projector device to determine which pins the TX and RX signals are carried on.
Be sure to always connect TX to RX and RX to TX.