argenta APE 800 Bedienings- en onderhoudshandleiding - Pagina 8

Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} argenta APE 800. argenta APE 800 16 pagina's. Burn-out furnaces

Burn-out furnace APE800 and APE800a

7. Temperature program selector

Temperature program selector, which is also called a driver, is a unit of two
cooperating modules – a temperature adjuster and an electronic clock. The main feature
which distinguishes it from an ordinary temperature adjuster is a function of temperature
increase control in a specific time.
Distinctive features
Amount of programmes
Amount of sections in the programme
Maximum temperature in a section
Maximum temperature increase
Maximum time of one section
Maximum delay of the programme running
Kind of adjustment
Adjustment with the priority
Glossary
program selector - (driver) – temperature adjuster with the control of temperature
increase, its holding and decrease in the furnace;
temperature increase – monitored temperature increase (heating) in the furnace
chamber, its value is defined with the use of the unit: [
rising line;
cooling – a kind of temperature increase, but in the opposite direction, its value is
defined with the unit:
temperature holding – holding the fixed temperature which has been reached in the
previous section, it is defined with the time unit: [min], it is illustrated with a straight
line;
programme – a list of subsequent sections which constitute the instructions concerning
the way of heating, set by the founder in the program selector;
section – a part of programme describing the performance of the program selector in a
given time;
delay – a function of the program selector which enables initiating the previously saved
programme with the time delay;
temperature priority – a function of the program selector which operates in the
background of each section, which is aimed at stopping the count of time in the section
when the furnace chamber is under-heated in the ±5
restoring of power supply – a function of the program selector that enables the
continuation of the burn out process after the power supply is restored in the situation
when power supply was cut off;
o
C/min, it is illustrated with the falling line;
2
16
o
800 [
C]
o
10 [
C/min]
1000 [min]
9999 [h]
PID
temperature
o
C/min], it is illustrated with the
o
C band;
2008-06-18
8