Drill a 65/80 mm diameter hole, insert a PVC pipe.
F
Use the screws to fix the rear panel to the wall.
H
Make sure the panel is flush against the wall. Any
space between the wall and unit will cause noise
and vibration.
YES
NO
The refrigerant tubes are on the right side of the
J
unit, while the drain hose can be on the right or on
the left side.
The drain tray is supplied with two outlets with tube
on one side and rubber plug on the other side.
How to reverse the drain hose position:
remove the drain hose by turning the metal clip
counterclockwise, then remove the rubber plug on
the other side of the unit. Replace them inverting
their position, use a screwdriver to insert the plug
correctly.
G
NO
K
7
Predispose the fixing of rear panel.
ø 5
Tubing connections on right or left side. Cut a
I
corner of the frame.
Running the multipolar power supply wire and the
connecting wire from indoor to outdoor unit (see
table for wires' size).
50 cm