Argo DD Handleiding voor installatie-instructies - Pagina 3
Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Argo DD. Argo DD 16 pagina's. Air conditioner without outdoor unit
• Supply the unit with a dedicated electrical line.
• Make install the unit by qualified personnel.
• Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage
shown on the nameplate.
• The installation of a double-pole switch, protected by 10 A fuses of the delayed type, upstream the electricity wall
socket, is recommended.
• Make sure that circuit breakers, fuses, etc, are of sufficient capacity to handle a start-up current of 20 A (generally less
then 1 second) - ONLY FOR ON/FF VERSION
• WARNING!
The air conditioner is provided with a time-guard system, which does not allow re-starting of compressor until after 3
minutes from a previous stop.
If necessary, get help
These instructions are all you need for most installation sites and maintenance conditions.
If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions.
In case of improper installation
The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to
follow the instructions in this document.
WARNING
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.
ONLY QUALIFIED, ExPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring are completed or reconnected and checked, to ensure the grounding.
• Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions
when wiring.
Improper connections and inadequate grounding can cause accidental injury and death.
• Ground the unit following local electrical codes.
• The Yellow/Green wire cannot be used for any connection different from the ground connection.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
• Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan.
• Do not use multicore cable when wiring the power supply and control lines. Use separate cables for each type of line.
When transporting
Be careful when picking up and moving the unit. Get a partner to help, and bend your knees when lifting to reduce strain
on your back. Sharp edges or thin aluminium fins on the unit can cut your fingers.
Move the unit only after removing the front panel and the bottom panel.
When installing
Make sure the wall is strong enough to hold the unit weight. It may be necessary to build a strong wooden or metal
frame to provide added support.
Do not mount the front panel and/or the bottom panel before fixing the unit to the wall.
GENERALITIES
1 -
OPERATING CONDITIONS
OPERATING LIMITS
COOLING
OUTDOOR TEMPERATURE
MAxIMUM CONDITIONS
ROOM TEMPERATURE
OUTDOOR TEMPERATURE
MINIMUM CONDITIONS
ROOM TEMPERATURE
HEATING
OUTDOOR TEMPERATURE
MAxIMUM CONDITIONS
ROOM TEMPERATURE
OUTDOOR TEMPERATURE
MINIMUM CONDITIONS
INDOOR ROOM
When wiring
43°C D.B.
32°C D.B./23°C W.B.
-15°C D.B.
10°C D.B./6°C W.B.
24°C D.B./18°C W.B.
27°C D.B.
-15°C D.B.
10°C D.B.
3
SPECIAL PRECAUTIONS
• Clean only with neutral detergents.
• Do not place objects on the unit.
• Do not pour liquids on the unit.
EN