VISCA Camera-Issued Messages
ACK/Completion Messages
Command
ACK
Completion
z = Device address + 8
Error Messages
Command
Syntax Error
Command Buffer Full
Command Canceled
No Socket
Command Not Executable
Network Change Message
Command
Network Change
Command Message
z0 4y FF
(y:Socket No.)
z0 5y FF
(y:Socket No.)
Command Message
z0 60 02 FF
z0 60 03 FF
z0 6y 04 FF
(y:Socket No.)
z0 6y 05 FF
(y:Socket No.)
z0 6y 41 FF
(y:Socket No.)
Command Message
z0 38 FF
Comments
Returned when the command is accepted.
Returned when the command has been executed.
Comments
Returned when the command format is different or when a command with illegal
command parameters is accepted.
Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
Returned when a command which is being executed in a socket specified by the
cancel command is canceled. The completion message for the command is not
returned.
Returned when no command is executed in a socket specified by the cancel
command, or when an invalid socket number is specified.
Returned when a command cannot be executed due to current conditions. For
example, when commands controlling the focus manually are received during auto
focus.
Comments
Issued when power is supplied to the camera.
8