2. Picture Frame Setting
Color bar chart standard picture frame
Subject
(40 cm from the front of the lens)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope and TV monitor
Adjustment page
F
Adjustment address
36, 37
Specified Value
A = B, C = D, t = 0 ± 0.1 msec
Setting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 36, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: F, address: 37, and set data: 40, and press the
PAUSE button of the adjustment remote commander.
4)
Adjust the camera direction, and set to the specified posi-
tion.
5)
Mark the position of the picture frame on the monitor dis-
play, and adjust the picture frame to this position in follow-
ing adjustments using "Color bar chart standard picture
frame".
Processing after Completing Adjustments:
1)
Select page: F, address: 37, and set data: 21 (NTSC) or set
data: 23 (PAL), and press the PAUSE button of the adjust-
ment remote commander.
2)
Select page: F, address: 36, and set data: 00 (NTSC) or set
data: 30 (PAL), and press the PAUSE button of the adjust-
ment remote commander.
3)
Select page: 0, address: 01, and set data: 00.
Check on the oscilloscope
1. Horizontal period
A=B
B
A
2. Vertical period
t=0 ± 0.1msec
Color on the TV monitor
Color bar chart picture frame
5-10
C=D
C
D
Fig. 5-1-6
V
Fig. 5-1-7
TV monitor picture frame
Fig. 5-1-8