9. Battery Down Adjustment

Set the battery end voltage.
Mode
Camera ON
Subject
Arbitrary
LCD display of the adjustment
Measurement Point
remote commander.
Measuring Instrument
Not required
Adjustment Page
F
Adjustment Address
58 to 5C
Connection
1)
Connect the regulated power supply and the digital voltme-
ter to the battery terminal as shown in Fig. 5-1-11.
Digital voltmeter
Regulated power supply
(6.1 ± 0.1Vdc)
Battery terminal
Fig. 5-1-11
Adjusting method:
1)
Adjusting the output voltage fo the regulated power supply
so that the digital voltmeter display is 6.1 ± 0.1 Vdc.
2)
Select page: 0, address: 01, and set data: 01.
3)
Decrease the output voltage of the regulated power supply
so that the digital voltmeter display is 5.30 ± 0.01 Vdc.
4)
Select page: 3, address: 0D, read the data, and this data is
named X
.
0
5)
Convert X
to decimal notation, and obtain X
0
(Refer to "Table 5-1-2. Hexadecimal-decimal conversion
table".)
6)
Calculate X
', X
', X
', and X
1
2
3
mal calculation).
Address: 59
X
Address: 5A
X
Address: 5B
X
Address: 5C
X
7)
Convert X
', X
', X
' and X
1
2
3
obtain X
, X
, X
and X
1
2
3
8)
Select page: F, address: 58, set data: X
button of the adjustment remote commander.
9)
Select page: F, address: 59, set data: X
button of the adjustment remote commander.
10) Select page: F, address: 5A, set data: X
button of the adjustment remote commander.
'.
0
' using follwing equations (deci-
4
' = X
' + 8
1
0
' = X
' + 32
2
0
' = X
' + 53
3
0
' = X
' + 64
4
0
' to hexadecimal notation, and
4
.
4
, and press the PAUSE
0
, and press the PAUSE
1
, and press the PAUSE
2
11) Select page: F, address: 5B, set data: X
button of the adjustment remote commander.
12) Select page: F, address: 5C, set data: X
button of the adjustment remote commander.
13) Select page: 0, address: 01, and set data: 00.
5-16 E
, and press the PAUSE
3
, and press the PAUSE
4