1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
C
0
4
0
0
Non-standard battery is used.
C
0
6
0
0
The battery pack temperature is high.
Memory card is unformatted.
C
1
3
0
1
Memory card is broken.
C
1
3
0
2
Disc access error.
E
2
0
0
0
Flash memory data are rewritten.
E
3
1
0
0
Drive fault
Difficult to adjust focus
E
6
1
0
0
(Cannot initialize focus).
Zoom operations fault
E
6
1
1
0
(Cannot initialize zoom lens).
The abnormalities in initialization of the focus
E
6
1
1
1
lens and the abnormalities in initialization of the
zoom lens occurred simultaneously.
Battery current value goes over the max
E
9
2
0
1
discharge current.
E
9
4
0
0
Fault of writing to or erasing the flash memory. Inspect the flash memory (IC7801 on the VC-611 (F) /(H) board).
Note 1 : Start the Adjust Manual in the Adjust Station and refer to the "DESTINATION DATA WRITE".
DCR-SR21/SR21E/SX21/SX21E_L2
Correction
Use the InfoLITHIUM battery.
Change the battery pack or replace it in a cool place.
Format the Memory card.
Insert a new Memory card.
Remove the power source. Reconnect it again and operate your
camcorder again.
Make flash memory data correct value. (Note 1)
Turn power off and turn power on again.
Inspect the lens block focus reset sensor (pin 8 of CN5401 on the
VC-611 (F) /(H) board) when focusing is performed when the focus
button is pressed in the focus manual mode, and the focus motor drive
circuit (IC5401 on the VC-611 (F) /(H) board) when the focusing is
not performed.
Inspect the lens block zoom reset sensor (pin 0 of CN5401 on the
VC-611 (F) /(H) board) when zooming is performed when the zoom
lever is operated, or the zoom motor drive circuit (IC5401 on the VC-
611 (F) /(H) board) when zooming is not performed.
Check both E: 61: 00 and E: 61: 10 of the self-diagnosis code.
Check the remaining battery power because this symptom may be
depended on the remaining battery level, and confirm whether or not
the symptom is occurred after replacing the battery. If the symptom
is still occurred, overhaul inspection is needed. Check each output of
DC-DC converter (IC4701) on the VC-611 (F) /(H) board with the AC
adaptor connected to DC JACK (J901) on the VC-611 (F) /(H) board.
(the minimum connection to periphery)
1-2E