DIGITIZE 425203-0001 Gebruikershandleiding - Pagina 10
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} DIGITIZE 425203-0001. DIGITIZE 425203-0001 11 pagina's.
If the batteries are not hooked up to the SEBB-6/24 during power up, or not
connected to each other, then the screen will display the following.
If the unit is displaying this message, check the connection between the two
batteries and between the batteries and the SEBB-6/24. If the connections are
secure, then test the batteries and replace any bad batteries with new ones.
Should the SYSTEM 3505 lose the connection to the SEBB-6/24, or should the
connection to the batteries be disconnected, or if the batteries should go bad,
then the SYSTEM 3505 will display the following trouble alarm:
If this alarm appears, check the cable between the two units and perform the
battery check, as described under the SEBB-6/24 "CHK OPEN BATTERY".
Once the link between the two units is reestablished, the SYSTEM 3505 will
display a RESTORE alarm.
If there is an AC power failure, the SYSTEM 3505 will display the following
TROUBLE alarm:
Once the AC power has been restored, the SYSTEM 3505 will display a
RESTORE alarm and the SEBB-6/24 will begin to RAPID CHARGE the
backup batteries.
6
Specifications Subject to Change Without Notice
SEBB-6/24 USER MANUAL
Chk Open Battery
SYSTEM 3505 HAS LOW or
MISSING BATTERY BACKUP
now in a TROUBLE state
at this location
AC power failure at
SYSTEM 3500/3000 or 3505
now in a TROUBLE state
at this location
DIGITIZE, INC. 700256-0001 REV. C 01/06