argon audio tt-2 Gebruikershandleiding - Pagina 8
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} argon audio tt-2. argon audio tt-2 12 pagina's.
Ook voor argon audio tt-2: Gebruikershandleiding (12 pagina's), Gebruikershandleiding (12 pagina's)
T T 2
3. Setup and usage
In order to achieve maximum performance and reliability with this record player you
should study these instructions for use carefully.
The Argon Audio TT2 turntable is supplied with a factory fitted and adjusted cartridge.
** The following instructions for adjusting the cartridge are provided in case the
cartridge is replaced by a different model at a later date.
During assembly and adjustment of the deck, small parts could be lost if not carefully
placed in a suitable receptacle.
Before starting assembly make yourself acquainted with the parts listed above and
correspondingly numbered in the technical drawings above. Separately packed items
are marked with an asterisk *.
Set-up
Make sure the surface you wish to use the turntable on is level (use a spirit level)
before placing the turntable on it.
Remove the two red transport screws (1) which secure the motor (22) during
transportation.
Fit the drive belt (3) around the hub (4) and the smaller diameter part of the motor
pulley (2). Avoid getting sweat or grease on the belt as these will deteriorate the
performance and reduce the belt's lifespan. Use absorbent kitchen paper to remove
any oil or grease from the outer edge of the hub and the belt. Fit the platter (5) and felt
mat over the spindle of the hub (4).
Store the two motor transport screws (1) in the original packaging so they are available
for any future transportation.
Cartridge down force adjustment
The counterweight (6) supplied is suitable for cartridges weighing between 3,5 - 5,5g.
An alternative counterweight for cartridges weighing between 6 - 9g is available as an
accessory part. Adjust the down force prior to installing the anti-skating weight.
Gently push and turn the counterweight (6) onto the arm tube stub. Lower the arm lift
and position the cartridge in the space between arm rest and platter. Carefully rotate
the counterweight (6) until the arm tube balances out. The arm should return to the
balanced position if it is moved up or down. This adjustment must be done carefully.
Do not forget to remove the cartridge protection cap if fitted.
Once the arm is correctly balanced return it to the rest. Hold the counterweight (6)
without moving it, and gently revolve the down force scale ring (6a) until the zero is in
line with the anti-skating prong (15). Check whether the arm still balances out.
Rotate the counterweight counter clockwise (seen from the front) to adjust the down
force according to the cartridge manufacturer's recommendations.
One mark on the scale represents 1 mN (= 0,1g / 0,1 Pond) of downforce.
The recommended downforce for the factory fitted cartridge is 17,5mN
w w w . a r g o n a u d i o . c o m
8