Step 2
Open the ejector lever in the front of the blade server.
Step 3
Gently slide the blade into the opening until you cannot push it any farther.
Step 4
Press the ejector lever so that it catches the edge of the chassis and presses the blade server all the way in.
Step 5
Tighten the captive screw on the front of the blade to no more than 3 in-lbs. Tightening with bare fingers only is unlikely
to lead to stripped or damaged captive screws.
Step 6
Power on the server. UCS Manager automatically reacknowledges, reassociates, and recommissions the server, provided
any hardware changes are allowed by the service profile.

Secure Digital (SD) Card Access

SD card slots are provided and one or two SD cards can be populated. If two SD cards are populated, they can be used in a mirrored
mode (Cisco UCS Manager 2.2.x and later required).
Do not mix 16 GB and 32 GB SD cards in the same server.
Note
Due to technical limitations, the 32 GB SD card has only 16 GB usable capacity (regardless of mirroring)
Note
in this particular server.
Figure 6: SD Card Slot Locations