4.Replacing Components

4.4. Replacing the Backplane

This component is NOT hot replaceable.
Requirements
The connected server has been shut down, and the server and the storage subsystem are switched off.
The power cables have been unplugged.
All other cables connected to the storage subsystem have been removed.
All HDD modules and dummy modules have been removed (as described in the operating manual).
The LED display has been removed (see section "Replacing the LED Display" on page 19).
The power supply units have been removed (as described in the operating manual).
The SAS expander module and the dummy blind right beside it have been removed (see section "Replacing
the SAS Expander Module" on page 13).
The storage subsystem has been removed from the rack cabinet (see operating manual).
Backplane case
Hard disk drives
Figure 6: Screws securing the backplane case on the chassis
Remove the screws (flat-head Phillips screws) securing the backplane case.
Remove the backplane case and deposit it bottom up.
Backplane
Chassis
17