Epson B81306 series Servicehandleiding - Pagina 24

Blader online of download pdf Servicehandleiding voor {categorie_naam} Epson B81306 series. Epson B81306 series 35 pagina's. Image scanner

B81306* Service Manual
TROUBLESHOOTING
5.1
When a trouble occurs, YOU can distinwish the defective unit by referring the symptoms of the
defect that indicated in ~canner indica~or.
you can easily identify what the problem.
Table 5-1. Symptom and Problem in Scanner Indicator
Symptom
Option Error
Table 5-2. Scanner indicates no error but no image data.
I
Cause
disconnected
Lamp is
defective
Sensor
Cover Open Sensor
Carriage Home
Position Sensor
Carriage Motor
The table below lists the symptom of certain defects, and
Problem
Cover open
Carriage error
Checkpoint
I
Check the connection between CN1
and Scanner.
Check the lighting of Lamp.
Table 5-3. Sensor Status
Point
Table 5-4. Motor
Motor
Cause
. Transparency Cover is open.
. Cover Open Sensor is defective.
. Lamp Carriage Mechanism is
defective.
. Carriage Home Position Sensor is
defective.
. Carriage Motor is defective.
I
Connect them correctly.
Replace the Lamp.
I
Signal Level
Resistance
5.3 Q* 10% (at250 C)
Traubleshooting
Solution
I
Status
Cover Close
Cover Open
At Home Position
Out of home Position
5-1