Servicing the Blade Server

Installing Memory

To install a DIMM in the blade server, follow these steps:
Procedure
Step 1
Open the DIMM connector latches. See callout 1 in the following figure.
Step 2
Press the DIMM into its slot, evenly applying pressure on both ends until it clicks. See callout 2.
Step 3
Close the DIMM connector latches. See callout 3.
Figure 18: Installing a DIMM

Supported DIMMs

The DIMMs supported in this blade server are constantly being updated. A list of currently supported and
available DIMMs is in the specification sheets at:
http://www.cisco.com/en/US/products/ps10280/products_data_sheets_list.html
Do not use any memory DIMMs other than those listed in the specification sheet. Doing so may irreparably
damage the server and require down time.

Memory Arrangement

Each UCS B260 M4 blade module has 48 slots for installing DIMMs—24 for each CPU. Each CPU has 24
DIMM slots spread over 8 channels. This blade server needs at least one DIMM attached to all populated
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v4 CPUs

Installing Memory

25