Ook voor Epson ProofPlus TM-H6000III: Producthandleiding (27 pagina's), Brochure (2 pagina's), Specificaties (2 pagina's), Brochure (6 pagina's), Gebruikershandleiding (32 pagina's), Ontwikkelingshandboek (26 pagina's), Ontwikkelingshandboek (32 pagina's), Handmatig (10 pagina's), Gebruikershandleiding (29 pagina's)

Epson ProofPlus TM-H6000III Ontwikkelingshandboek
refer to the CHK_DI_READ_AREA command reference
regarding the effective reading area.
When CHK_DI_EXTEND_FILTER is set, the EndInsertion
method scans an image after setting the filtering area. Please
refer to the CHK_DI_IMAGE_FILTER command reference
regarding the effective reading area.
When CHK_DI_EXTEND_FILTER is set, the EndInsertion
method scans an image after setting the filtering area. Please
refer to the CHK_DI_IMAGE_FILTER command reference
regarding the effective reading area.
When CHK_DI_EXTEND_ATTACHED is set, the EndInsertion
method sets an embedded character string to the header of the
read image data.
Please refer to the CHK_DI_ATTACHED_DATA command
reference regarding the embedded character string.
When CHK_DI_EXTEND_TMSTORE is set, the EndInsertion
method stores the image data in the Storage Memory of the
device.
When the device does not have Storage Memory
function, this command is unable to use.
For Executing the EndInsertion method under the above flag, it
is required to number storing memory by using the
CHK_DI_TMSTORE_SET_INDEX command in advance.
Please
refer
to
command reference on how to set memory ID (number).
When storing image data in the Storage Memory is done
successfully, the Work Memory does not acquirer any data.
Therefore, the contents of the working buffer memory area are
not updated under the flag. When the data image storing is
failed,
the
CHK_DI_TMSTORE_ERRORMODE
Please
refer
to
command reference for error reaction.
Values other than CHK_DI_EXTEND_DEFAULT can be
specified simultaneously using the OR operation.
The default value is CHK_DI_EXTEND_DEFAULT.
CHK_DI_EXTEND_PRESCAN,