COUNTING MORE PARTS
After the unit weight has been determined or entered it is possible to use the
scale for parts counting. The scale can be tared to account for package
weight as discussed in an earlier section.
After the scale is tared, the items to be counted are added and the "Count"
display will show the number of items computed using the weight and the unit
weight.
It is possible to increase the accuracy of the unit weight at any time during the
counting process by entering the count displayed then pressing the SMPL
key. You must be certain the quantity displayed matches the quantity on the
scale before pressing the key. The unit weight will be adjusted based upon a
larger sample quantity. Use of larger sample sizes will give greater accuracy
when counting larger quantities.
AUTOMATIC PART WEIGHT UPDATES
The scales will automatically update the unit weight when a sample equal to
or less than the sample already on the platform is added. A beep will be
heard when the value is updated. It is wise to check that the quantity is
correct when the unit weight has been updated automatically. This feature is
turned off as soon as the number of items added exceeds the count used as
a sample. This feature may be enabled or disabled in the scale setup mode.
PRESET CHECK-WEIGHING
Check-weighing is a procedure to cause an alarm to sound when the weight
on the scale falls within a preset range. The weight range is set as follows.
1. Press the ALARM key while the scale is either loaded or unloaded. Hi
will show in the weight display
2. Key in the high limit weight value and press the ALARM key again.
3. Now Lo will be displayed. Key in the low limit weight value and press
the U.Wt key to store the value and return to the normal weighing
mode.
4. To disable the function, follow the above steps entering " 0" for the high
and low preset values
PRESET COUNTING ALARM
Pre-Set Counting is a procedure to cause an alarm to sound when the
quantity of items on the scale falls within a preset range. The item count
range is set as follows.
SCALES usa © 2004