Remove all weight from the platform, and press the ZERO key to zero
the display.
Press the P.Tare key and the unit weight display will flash PrEtA
Enter the value for the Tare weight including decimal values (50.00)
using the keypad, press P.Tare to store the tare value. The weight will
show a negative value equal to the tare.
Place the container on the platform. The display will then show the
weight of the container minus the tare weight. Then when the full
container is put on the platform the tare value will be subtracted from
the gross weight displaying only the net weight of the contents.
PARTS COUNTING
SETTING UNIT WEIGHT
In order to do parts counting it is necessary to know the average piece weight
of the items to be counted. This can be done by weighing a known number of
the items and letting the scale determine the average unit weight or by
manually entering a known weight using the keypad.
WEIGHING A SAMPLE TO DETERMINE THE UNIT WEIGHT
To determine the average weight of the items to be counted it will be
necessary to place a known quantity of the items on the scale and then
to key in the number of items being weighed. The scale will then divide
the total weight by the number of items and display the average unit
weight.
Zero the scale by pressing the ZERO key if necessary. If a container is
to be used, place the container on the scale and tare as discussed
earlier.
Place a known quantity of items on the scale. After the weight display
is stable enter the quantity of items using the numeric keys followed by
SMPL key. The number of units will be displayed on the "Count"
display and the computed average weight will be shown on the "Unit
Weight" display.
As more items are added to the scale, the weight and the quantity will
increase.
If the scale is not stable, the calculation will not be completed. If the
weight is below zero, the " Count" display will show all dashes.
The SMPL key may be pressed during the counting to update the unit
weight.