aculab Prosody X Installatiehandleiding - Pagina 8

Blader online of download pdf Installatiehandleiding voor {categorie_naam} aculab Prosody X. aculab Prosody X 20 pagina's. 1u high availability chassis
Ook voor aculab Prosody X: Snelstarthandleiding (13 pagina's)

Prosody X Installation guide
1.2

Powering the Prosody X HA 1U on

Connect power cords to the Prosody X 1U HA chassis according to the following
procedure:
Check that the electrical outlet is grounded and it is within the permitted range
shown on the rating label
For the AC chassis, plug the power cords into the AC power IEC inlet socket on
the rear of the Prosody X 1U HA chassis
IEC inlet PSU 1

Figure 1-3 AC power inlet connectors

For the DC chassis, connect a suitably current rated and insulated wire pair to
each terminal pair observing the correct polarity, which is labelled as 0V and -48V
adjacent to the screw terminals
DC inlet screw
terminals PSU 1
0V

Figure 1-4 DC power inlet terminals and polarity

Connect the other ends of the power cords/wire pairs into a suitable electrical
outlet and turn on the supply
Switch on both PSU modules at the rear
Press the "standby" ( ) button on the front panel
Each power module has a green LED showing that it is powered up
Front panel PSU Status LEDs show that both power modules are connected and
switched on
The Standby button uses the
The system may take several minutes to initialise following power on.
8 of 25
IEC inlet PSU 2
DC inlet screw
terminals PSU 2
0V
-48V
-48V
NOTE
symbol on the front of the Prosody X 1U HA chassis.