Epson EMP-8100 Communicatiehandleiding - Pagina 19

Blader online of download pdf Communicatiehandleiding voor {categorie_naam} Epson EMP-8100. Epson EMP-8100 20 pagina's. Esc/vp level 6 serial communication manual
Ook voor Epson EMP-8100: Bedieningshandleiding (14 pagina's), Specificaties (1 pagina's)

Epson EMP-8100 Communicatiehandleiding
06 OPTION
Command
structure
STX
Size
Type

11 : Message

Controls the screen state when no signal is input.
[Parameter]
Data relating to screen state when no signal is input
0x00: Non-display
0x01: Black
0x02: Blue
0x03: Logo
Set
1D
0009
Get
1D
0008
Initialize
1D
0008

14 : V Keystone

Adjusts the projected image in the vertical direction during keystone correction.
[Parameter]
Vertical Keystone Value (1 byte)
Setting range: 80 to FF, 00 to 7F
Set
1D
0009
1D
0008
Get
1D
0008
Initialize

15 : DelayON

Controls the DelayOn ON/OFF setting.
When set to ON, the lamp is on when power is being supplied through the power cable. When set to OFF, this function is disabled.
[Parameter]
Data relating to DelayON ON/OFF setting (1 byte)
0x00: OFF
0x01: ON
Set
1D
0009
Get
1D
0008
Initialize
1D
0008

16 : Comp1/DV1 selection

Sets the Computer1 or DVI image bus independent of he I/F panel slide switch setting.
Gets the current image bus setting (Computer or DVI).
[Parameter]
Data relating to image bus setting (1 byte)
0x00: Computer1
0x01: DVI
1D
0009
Set
1D
0008
Get

19 : Computer2 input format

Controls the input format for the Computer2 terminal.
[Parameter]
Data relating to Computer2 terminal input format
0x00: RGB
0x01: YCbCr
0x02: YPbCr
Set
1D
0008
Get
1D
0008
Initialize
1D
0008
ESC/VP Level 6 Serial Communication Manual (Abridged Edition)
Apply
Attribu
From
Group
Item
te
To
01
01
06
11
02
01
06
11
03
01
06
11
01
01
06
14
02
01
06
14
03
01
06
14
(Applicable models: EMP-8100/8150/9100/7700)
01
01
06
15
02
01
06
15
03
01
06
15
01
01
06
16
02
01
06
16
(Applicable models: EMP-7600/5600)
01
01
06
19
02
01
06
19
03
01
06
19
Param
Check-
STX
Size
eter
sum
0008
PARA
CS
1D
000A
0009
--
CS
1D
000A
0009
--
CS
1D
000A
0008
PARA
CS
1D
000A
0009
--
CS
1D
000A
0009
--
CS
1D
000A
0008
PARA
CS
1D
000A
0009
--
CS
1D
000A
0009
--
CS
1D
000A
0008
PARA
CS
1D
000A
0009
--
CS
1D
000A
0008
PARA
CS
1D
000A
0009
--
CS
1D
000A
0009
--
CS
1D
000A
19 of 20
Reply
Attribu
From
Group
Item
te
To
81
10
06
11
C1
82
10
06
11
C2
83
10
06
11
C3
81
10
06
14
C1
82
10
06
14
C2
83
10
06
14
C3
81
10
06
15
C1
82
10
06
15
C2
83
10
06
15
C3
81
10
06
16
C1
82
10
06
16
C2
81
10
06
19
C1
82
10
06
19
C2
83
10
06
19
C3
Param
Check-
eter
sum
--
CS
PARA
PARA
CS
PARA
CS
--
CS
PARA
PARA
CS
PARA
CS
--
CS
PARA
PARA
CS
PARA
CS
--
CS
PARA
PARA
CS
--
CS
PARA
PARA
CS
PARA
CS