Toshiba 14AR22 Servicehandleiding - Pagina 11
Blader online of download pdf Servicehandleiding voor {categorie_naam} Toshiba 14AR22. Toshiba 14AR22 30 pagina's.
14AR22
SERVICE
POSITION
FMWS
FM WINDOW SELECTION
SM0
SOUND MUTE BIT 0 (SM0)
SM1
SOUND MUTE BIT 1
AGC0
IF AGC SPEED BIT 0
AGC1
IF AGC SPEED BIT 1
FOA-FE
PHI 1 TIME CONSTANT FOR FE
FOB-FE
PHI 1 TIME CONSTANT FOR FE
FOA-AV
PHI 1 TIME CONSTANT FOR AV
FOB-AV
PHI 1 TIME CONSTANT FOR AV
FSL
FORCED SLICING LEVEL FOR VERTICAL SYNC.
HP2
SYNCHRONISATION OF OSD/TEXT DISPLAY
RGBL
RGB BLANK
V-CHIP
V-CHIP
MTS
MTS DECODING ENABLED
DEMO
DEMO MODE
CLOCK
REAL TIME CLOCK / ON TIMER
E-SAVE
ENERGY SAVE
P_PREF
PERSONAL PREFERENCE PROGRAM
UNIV+
UNIVERSAL PLUS
SPEAKER
SPEAKER ON/OFF
FAO
FIXED AUDIO OUT
VIEW-TM
VIEW TIMER
FRENCH
FRENCH LANGUAGE
EZ-SETUP
EZ SETUP / AUTOPRESET
W-TEMP
WHITE TEMP OR FAVORITE COLOR
AV
AV ENABLED OR DISABLED
AV2
AV2 ENABLED OR DISABLED
DSK
DYNAMIC SKIN CONTROL
RPO0
RATIO PRE- AND OVERSHOOT BIT 0
RPO1
RATIO PRE- AND OVERSHOOT BIT 1
AGN
GAIN FM DEMODULATOR
AUTO-OFF
AUTO SWITCH OFF ENABLED
Holding down to short JA137 & JA138 and turn on the main power SW will automatically write the initial values into
IC1003.
This is only can done when a new EEPROM is used. (Judge with the first 4 bytes.)
PART REPLACED
NECESSARY
IC801
IC1003
CRT
ADJUST ITEM
Table - A
ADJUSTMENT
UNNECESSARY
X
X
X
Table - B
DATA
RANGE
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(AUTOPRESET) or
1(EZ SETUP)
0(FC) or 1(WT)
0(without ext. source) or
1(with external source)
0(1 input) or 1(2 input)
0(disable) or1(enable)
0(disable) or1(enable)
0(disable) or1(enable)
0(normal) or1(+6dB)
0(disable) or1(enable)
Data is stored in IC1003.
Holding down to short JA137 & JA138 and turn on the main
power SW will automatically write the initial values into IC1003.
This is only can done when a new EEPROM is used. (Judge
with the first 4 bytes.)
Adjust items related to picture tube only.
10
REMARK
INITIAL VALUE FIX/ADJ
0
FIX
1
FIX
0
FIX
1
FIX
0
FIX
0
FIX
0
FIX
1
FIX
1
FIX
0
FIX
0
FIX
0
FIX
0
FIX
0
FIX
1
FIX
1
FIX*
14LK22→1/ 14MR10→0
1
FIX
0
FIX
0
FIX
0
FIX
0
FIX
1
FIX*
14LK22→1/ 14MR10→0
0
FIX
1
FIX
0
FIX
0
FIX
0
FIX
0
FIX
0
FIX
0
FIX
0
FIX
1
FIX
NOTES