5.11 Relays

MSI-8000HD can be equipped with up to three relays for process
The
systems.
In the non meter MSI-8000HD, relays are programmed on the unit that the
Note
8000HD is "talking" to.
Two independant relays are installed and are wired out to 4 pins on a M12 connector.
The connecting cables are shown in the table below.
MSI Part No.
13287
14626
Alternately they can use a field wireable connector
14622
14623
14624
14625
5.11.1 Relay Options
All Relays are Normally Open (1 Form A). Specifications of relay options:
AC/DC Coil Relay
- AC/DC Coil Relay: 13452 PA1a-5V. 4A Fuse: 13165
- AC Rating: 250VAC @4A.(limited by connector/cordset rating to 4A
continuous)
- DC Rating: 4A @ 30VDC, 0.4A @ 100VDC
Best choice for 90% of applications.
AC/DC SSRs (Solid State Relays).
Better for battery powered units and mates well with 24VDC industrial power
supplies
- AC/DC SSR 60Vpk, 2.7A: 13178 AQZ202D. 2A Fuse: 13193
AC/DC SSRs (Solid State Relays).
For 115VAC operation when SSRs are preferred
- AC/DC SSR 200Vpk. 0.9A: 13180 AQZ207D. 0.75A Fuse: 14563
Other Available Relays
- AC/DC SSR 100Vpk, 2A: 13179 AQZ205D. 1.5A Fuse: 14562
- AC/DC SSR 400Vpk, 0.45A: 13181 AQZ204D. 0.375A Fuse: 14564 (Use
limited to 250VRMS due to connector and Cordset limitations)
- DC Only SSRs
- DC SSR 60Vpk, 4A: 13182 AQZ102D. 3A Fuse: 14565
- DC SSR 200Vpk, 1.3A: 14566 AQZ107D. 1A Fuse: 14561
Normally open relays (1 Form A) can be made to function as normally closed
Note
(1 Form B) by programming the setpoint as a less than type. If the 8000HD is
turned off or loses power, they will open.
PVC 4m, rated to 250VRMS, 4A
PVC 10m, rated to 250VRMS, 4A
Straight for cable 4-6mmOD, (RLWS 156256)
Right angle for 4-6mm
Straight for cable 6-8mmOD
Right angle 6-8mmOD
Description
.
control or safety
COMM Set Up
31