Cru Power HT-S-3000-48 Handmatig

Blader online of download pdf Handmatig voor {categorie_naam} Cru Power HT-S-3000-48. Cru Power HT-S-3000-48 3 pagina's. Dc to ac power inverter

Cru Power HT-S-3000-48 Handmatig
DC to AC
No Bypass Function
Remote
control-LED
DIP Switch
Function
AC Output
Pure sine wave output (<2% THD).
Input & Output fully isolation design.
High surge in motor start capacity.
Thermal control fan.
Frequency 50/60HZ switchable.
Auto restart.
Power saving function ( <10W load )
Firstly, thank you for purchase our product.Please read this manual carefully before installing
or using this product.
Model No.
AC Voltage
Continuous Power
Surge Power
OUTPUT
Waveform
Frequency
AC Regulation
Receptacles
DC Current
DC noload current under normal mode.
DC noload current under power saving mode.
DC Voltage
INTPUT
Voltage Range
Efficiency (Typ.)
DC Connector
Fuse
Battery low alarm
Battery low shut down
Over voltage
PROTEC-
Over Temperature
TION
Short Circuit Protection
Battery polarity
Over Load
WORKING TEMP.
ENVIRON-
WORKING HUMIDITY
MENT
STORAGE TEMP., HUMIDITY
TEMP.COEFFICIENT
EMI Conduction & Radiation
EMS Immunity
SAFETY
LVD
UL
Dimension (L*W*H)
OTHERS
NET. Weight
Gross Weight (With Cable)
Optional
Byass function
EXTRA
FUNTION
DC noload current under normal mode.
DC noload current under power saving mode.
Low AC input volt transfer to inverter mode.
INPUT
Low AC input volt recovery to AC mode.
High AC input volt transfer to inverter mode.
High AC input volt recovery to AC mode.
Input AC terminal
Connector
Output AC Terminal
Receptacles
Introduction
This model is used in a wide range of
application including remote homes, RVs,
sailboats and powerboats.
It will operate most televisions and VCR,
personal computers, small appliances
and tools such as drills, sanders, grinders,
mixers and blenders.To get the most out
of the power inverter, it must be installed
and used properly.
All manuals and user guides at all-guides.com
Power inverter manual
With Bypass Function
Remote
control-LED
DIP Switch
Function
SPECIFICATIONS
HT-S-3000-12
HT-S-3000-24
100VAC/120VAC/230VAC
3000W
6000W
PURE SINE WAVE
50/60HZ±3%
±5%
YES, 1pc
300A(12V) / 150A(24V) / 75A(48V)
1.0A(12V) / 0.5A(24V) / 0.25A(48V)
0.12A(12V) / 0.06A(24V) / 0.03A(48V)
12V/24V/48V
10-16VDC(12V) / 20-32VDC(24V) / 40-61V(48V)
Cable*1pc
15pcs
Pure Sine Wave
10.5±0.5V(12V) / 21±1V(24V) / 42±2v(48v)
10±0.5V(12V) / 20±1V(24V) / 40±2V(48V)
16±0.5V(12V) / 32±1V(24V) / 61±2V(48V)
55°C±5°C
Shut-off
Fuse Burn out
re-start 1 time, shut down if failed
-15°C~+45°C
20%~90% RH non-condensing
-30°C~+70°C/-22°F~+158°F, 10~95% RH
±0.05%°C(0~55°C)
Compliance to EN55022 class B, 72/245/CEE, 95/54/CE
Compliance to EN61000-4-2, 3
Compliance to EN60950
UL458
570*274*105mm
9.8kgs
10.8kgs
Yes
1.0A(12V) / 0.5A(24V) / 0.25A(48V)
0.4A(12V) / 0.2A(24V) / 0.1A(48V)
90Vac+/-5% or 180Vac+/-5%
95Vac+/-5% or 190Vac+/-5%
132Vac+/-5% or 265Vac+/-5%
125Vac+/-5% or 250Vac+/-5%
Yes, hard wiring.
Yes, hard wiring.
No
Please read the instructions in this manual before
installing and using this model.
Quick hook – up and testing
If you would like to quick hook-up the power
inverter and check its performance before
going ahead with your installation, please
follow these guidelines:
1. Unpack and inspect the power inverter,
check to see that the power switch is in the
OFF position.
Breaker
DC Input
Battery terminals
Connect to battery or other power source.
"+" is positive (Red),
"-" is negative(Black),
Reverse polarity connection will blow internal
fuse and may damage inverter permanently.
2. Connect the cables to the power input
HT-S-3000-48
3. Connect the cable from the negative terminal
4. Before proceed further, carefully check that
5. Connect the cable from the positive terminal
6. Set the power switch to the ON position.
7. Set power inverter switch to the OFF
8. Set power inverter switch to the ON
HT-S-3000
Rear view
Ventilation window
Do not obstruct, allow at
least one inch for airflow.
terminals on the rear panel of power inverter.
The red terminal is positive (+) and black
terminal is negative (-).
Connect the cables into the terminals and
tighten the wing nut to clamp the wires
securely.
of the inverter to the negative terminal of
the power source. Make a secure connection.
Loosely tightened connectors result in
excessive drop and may cause overheated
wires and melted insulation.
cable you have just connected connects
from the negative terminal of inverter to the
negative output terminal of the power source.
Reverse polarity connection will blow
a fuse in inverter and may permanently
damage the inverter. Damage caused
by reverse polarity connection is not
covered by our warranty.
of inverter to the positive terminal of the
power source. Make secure connection.
You may observe a spark when you make
this connection since current may flow to
charge capacitors in the power inverter.
Do not make this connection in the presence
of flammable fumes, explosions or fire
may result.
Check the meters and indicators on the
front panel of the inverter.
If does not, check your power source and
the connections to inverter. The other
indicators should be off.
position, the indicator lights may blink.
Plug the test load into the AC receptacle
on the front panel of the inverter. Please
keep switch in off position.