Aeon Labs MultiSensor 6 Gebruikershandleiding - Pagina 6

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Aeon Labs MultiSensor 6. Aeon Labs MultiSensor 6 10 pagina's. Z-wave multisensor

5.2 Association Command Class
MultiSensor supports 1 association group.
Group 1 is assigned to the Lifeline association group and can add max 5 association nodes.
When the PIR motion sensor is triggered, the MultiSensor will send Basic Set (0xFF) to the associated
nodes. If no any PIR motion on an interval time (configurable), the MultiSensor will send Basic Set (0x00)
to the associated nodes.
The automatically report of temperature, humidity, luminance and ultraviolet (configurable) also can be
sent to associated nodes.
5.3 Association Group Info Command Class
5.3.1 Association Group Info Report Command Class
Profile: General: NA (Profile MSB=0, Profile LSB=0)
5.3.2 Association Group Name Report Command Class
Group 1: Lifeline
5.3.3 Association Group Command List Report
Command List Report: 20 01 30 03 80 03 31 05 71 05 84 07.
COMMAND_CLASS_BASIC
COMMAND_CLASS_SENSOR_BINARY
COMMAND_CLASS_BATTERY
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_NOTIFICATION_V3
COMMAND_CLASS_WAKE_UP
5.4 Manufacturer Specific Report
Parameter
Manufacturer ID 1
Manufacturer ID 2
Product Type ID 1
Product Type ID 2
Product ID 1
Product ID 2
5.6 Configuration Set Command Class
7
6
Default
Parameter Number Definitions (8 bit):
BASIC_SET
SENSOR_BINARY_REPORT
BATTERY_REPORT
SENSOR_MULTILEVEL_REPORT
NOTIFICATION_REPORT_V3
WAKE_UP_NOTIFICATION
5
4
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter Number
Reserved
Configuration Value 1(MSB)
Configuration Value 2
Configuration Value n(LSB)
Value
US/EU/AU=0x00 CN=0x01
US/EU/AU=0x86 CN=0x6A
EU=0x00, US=0x01, AU=0x02 CN=0x1D (29)
0x03
0x00
0x64 (100)
3
2
.........
1
0
Size