Ariston 3300761 Technische instructies - Pagina 19
Blader online of download pdf Technische instructies voor {categorie_naam} Ariston 3300761. Ariston 3300761 32 pagina's. Condensing wall thermal power plant
Machine Translated by Google
Gas regulation table
Lower Wobbe Index (15 ° C, 1013 mbar) (MJ / m3)
Slow ignition
Maximum heating power
Minimum fan speed (%)
Maximum fan heating speed (%)
Maximum domestic hot water fan speed (%)
Debit gaz max/min
(15°C, 1013 mbari) (nat
- m3/h
CHANGE OF GAS TYPE
CHANGING OF THE TYPE OF GAS FROM
NATURAL GAS (G20) TO PROPANE GAS
(G31) OR REVERSE, IS PROHIBITED.
Parameter
max domestic hot water
max heating
min
Auto function
The function allows the boiler to automatically adapt to the operating
mode (radiator temperature) and to the external conditions, in order
to reach and keep the set ambient temperature constant.
Depending on the connected peripherals as well as the number of
zones controlled, the boiler automatically regulates the temperature
on the flow circuit.
So set the parameters that interest you
(see settings menu).
To activate the function, enter a
parameter 224.
For detailed information, refer to the
CHAFFOTEAUX Thermoregulation Manual.
Example 2:
Single zone installation (high temperature) with on / off room
thermostat and external probe:
in this case it is necessary to enter the parameters:
421 - Activation Thermoregulation with sensors
- select 01 = external probe only
422 - Select the thermoregulation curve -
select the curve that interests you based on the type of
installation, appliance, thermal insulation of the building, etc.
423 - The parallel movement of the curve - if applicable - can allow
you to lower or increase the set-point temperature (can also
be changed by the user with the heating temperature control
cap, which, if the Auto
moving the curve in parallel).
PUTTING INTO SERVICE
HS PREMIUM
24 EU
G20
45,67
220
35
231
60
233
10
234
83
232
83
2,4
2,4
0,44
function
is deactivated, has the role of
/
19
30 EU
G20
45,67
35
60
12
82
820
3,07
3,07
0,63