Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be added to
an existing wireless network to communicate with the devices of this network. This process is
called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are
initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion
respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right
on the device.
Inclusion
1. Open the housing.
2. Remove the battery protection.
3. Press the tamper on the side of the appliance three times quickly.
Exclusion
1. Open the housing.
2. Press the tamper on the side of the appliance three times quickly.

Product Usage

Once installed the sensor will report "open" and "close" status changes to a central Z-Wave controller
using notification commands. Additionally, the sensor can directly control other devices using association
group 2. The device is protected by a tamper switch.
Link testing
When activated by configuration parameter #5 the device can perform a link test. Double-clicking the
tamper will start the process. As a result, the GREEN LED will blink two times in case of success and the
RED LED will blink two times in case of failure.
Notifications
The device sends the following notifications to the central controller:
Window Opened(0x06 - 0x16)
Window Closed(0x06 - 0x17)
Tamper Removed(0x07 - 0x03)

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about
the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by
sending out a Node Information Frame. Beside this it may be needed for certain network operations to
send out a Node Information Frame. To issue a NIF execute the following action: Press the tamper once
Quick trouble shooting
Here are a few hints for network installation if things don't work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.