Remove the cover of Door / Window Sensor 7
Press and hold tamper switch for 5 seconds until the red LED blinks.
Release the tamper switch
Immediately press and hold the tamper switch for 5 seconds until the red LED blinks.

Association Groups.

Association groups allow Door Window Sensor 7 to directly control Z-Wave devices without the use of a Z-Wave
Controller to maximize communication efficiency. 
Group Number Max Nodes Description
1
5
2
5
3
5
4
5

Parameter Configurations.

Parameter 3: Door/Window State.
This parameter allows setting Door / Window Sensor 7 state when the magnet is close to the sensor.
Size: 1 Byte, Default Value: 0

Setting Description

0
closed when the magnet is near
1
opened when the magnet is near
Parameter 4: Visual LED Indications.
This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life.
Size: 1 Byte, Default Value: 7, Range: 0 - 7
Setting Description
0
no indications
1
indication of opening/closing status change
indication of wake up (1 x click or
2
periodical)
4
indication of device tampering
Parameter 5: Range test after double click.
Allows enabling the activation of Z-Wave range test with double click of a Tamper Switch 2.
Size: 1 Byte, Default Value: 0
Setting Description
0
Disable
1
Enable
Parameter 6: Group 2 Association Triggers.
https://help.aeotec.com/support/solutions/articles/6000230382-door-window-sensor-7-basic-user-guide-zwa011-zwa041-
Aeotec Door Window Sensor 7 Basic guide : Aeotec Help Desk
Lifeline
Control devices when a magnet or external dry
contacts trips
Sends our alarm message when magnet controlled or
external dry sensor trips.
Sends alarm messages when tamper is tripped
7/9