Set Eco Evo Plus Mode
together with the "ECO EVO" mode (see "ECO EVO Function" paragraph), the
temperature is set automatically by the product itself. The User can set the time
at which the hot water should be ready. The "+"/ "-" and "SET" buttons are
deactivated in this mode. If pressed, the display shows the sign "ECO" for three
seconds. This operating mode guarantees a greater energy saving.
N N . . B B . .
For the temperature setting in Manual and Timer mode, if the user does not
make any selection for 3 seconds, the system keeps the last setting. For all the
other settings, the system saves the choice just after the "SET" button is pressed.

Diagnostic / Reset

When one of the malfunctions described below occurs, the product will enter in
a "fault status" and the HMI will display a blinking error code. In the "fault status",
the "HEATING" LED also blinks (Fig.8 as an example).
The error codes are the following:
-
E02  Water Overheating
-
E10 – E11  NTC Sensor Fault
-
E04  Dry Heating
-
E50 – E60 – E80 – E92  Maintenance Request
-
E90  Heating element Fault
-
driP  Leakage Detected (see Leakage Detection paragraph)
Reset: To reset the product, switch it off and on again by the pressing
If the cause of the malfunction disappears immediately following the reset
process, the product will resume normal operation. If the display still shows the
error code, then it is necessary to contact the Ariston Call Centre on 010 745 9911.
: When one of the timer program functions is used
Fig.8
- 7 -
button.