Installation Method
Note: the product must be installed by qualified personnel.
A. Drill two holes of 100mm in depth on the solid wall in horizontal/vertical direction by percussion drill
based on the exact model(b).
B. Insert the expansion bolt into the holes, then screw tightly the hook and let it upward (Figure A)
C. Put the hand rack which is on the upper of electric water heater,on the hook of expansion bolt cor-
rectly and tightly.
D. All the tubes are G1/2', Connect properly the quipped water mixing valve,
One-way release valve,three-way inlet tube and three-way outlet tube according to different models
E. While in the case of little space,the electric water heater can be installed in the places where are
weather resistant,but in order to protect the thermal loss of the pipeline,the installation location
should be as close as possible to the water using location
F. Before use,you should completely check and verify the unit current is matching with the power sup-
ply and the wire capacity etc
Warning: you should check the wall which is to be installed the electric water heater onto is solid and
can undertake the weight of full capacity,the expansion bolts are prohibited installed in the joint part.
Figure A
distance
Figure B
7 / EN