Aeotec Water Sensor 7 Pro Snelstarthandleiding - Pagina 4
Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Aeotec Water Sensor 7 Pro. Aeotec Water Sensor 7 Pro 8 pagina's. Water sensor
Ook voor Aeotec Water Sensor 7 Pro: Handmatig (3 pagina's), Gebruikershandleiding (9 pagina's), Gebruikershandleiding (13 pagina's), Gebruikershandleiding (14 pagina's), Gebruikershandleiding (9 pagina's)
devices that will receive controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored
in the respective association group will receive the same wireless command wireless command, typically a
'Basic Set' Command.
Association Groups:
Group Number
1
2
3
4
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt
the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ...
255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to
200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic
applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 3: Visual LED Indications
This parameter defines when LEDs will indicate events. Disabling all indications may extend battery life.
Value 0 means - No Indications.
Size: 1 Byte, Default Value: 7 (values 1 + 2 + 4 summarized)
Setting
1
2
4
Parameter 4: Range Test after double click
Allows to enable the a Z-Wave range test with double clicking the tamper switch. The green LED indicates the
sensor is in the range and the red LED indicates, its out of range.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 5: 2nd Association Group Trigger
This parameter defines the status of the water leakage that causes sending a BASIC command to all devices of
Association Group 2.
Size: 1 Byte, Default Value: 0
Setting
0
1
Maximum
Description
Nodes
5
Lifeline
5
Control devices when water leakage is detected
5
Sends out alarm message when water leakage is
detected
5
Sends out alarm messages when tamper is tripped
Description
Water Leakage Status Change
Wake Up
Device Tampering
Description
Disabled
Enabled
Description
Switch after Water Leakage Start and Stop
Switch after Water Leakage Start