Testing Health Connectivity.
NOTE - This health detection function is only good for determining the direct connection to the gateway (within
communication distance to your gateway without any other repeater nodes).
You can determine the health of your Recessed Door Sensor 7 connectivity to your gateway using its manual
button press, hold, and release function which is indicated by the LED.
Your gateway/controller/hub must support displaying Z-Wave device health in order for you to see the health of
your Recessed Door Sensor 7 to your Z-Wave gateway.
Follow these steps to test the health of your Recessed Door Sensor 7 to your Z-Wave gateway/controller/hub:
Press and hold the Z-Wave Button for 5-10 seconds to test the communication health your Recessed Door
Sensor 7.
@1 second, LED will turn off.
@2 seconds, LED will breath its LED
@5 seconds, LED will flash its LED
Release the Action Button to test the health.
If the LED sped up it's flashing, you have held it for too long.
Once the test is finished, the Recessed Door Sensor 7 will forward a Power Level Report command to your Z-
Wave gateway to display the communication quality. Some gateways do not support Power Level Command
Class in its interface and may not show.
More Advanced Configurations.
Recessed Door Sensor Gen7 has a longer list of device configurations that you can do with Recessed Door Sensor
Gen7. These are not exposed well in most gateways, but at the least, you can manually set configurations through
most Z-Wave gateways available. These configuration options may not be available in a few gateways.
You can find the configuration sheet here: https://aeotec.freshdesk.com/helpdesk/attachments/6092013991
(https://aeotec.freshdesk.com/helpdesk/attachments/6092013991)
If you have any questions on how to set these, please contact support and let them know what gateway you are