Aeotec AEOEZW116 Handmatig - Pagina 3
Blader online of download pdf Handmatig voor {categorie_naam} Aeotec AEOEZW116. Aeotec AEOEZW116 16 pagina's. Single nano switch with measuring
Ook voor Aeotec AEOEZW116: Snelstarthandleiding (11 pagina's)
30-09-2020 13:25
by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform
the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be u
Set Parameter 255
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms m
assembly of the product, the voltage network has to be switched off and ensured against re-switching.
Installation
Notes for the wire connection ports:
N ? Power input for neutral
L ? Power input for live
IN ? Input for load power supply
OUT1 ? Output for load 1
OUT2 ? Output for load 2
S1 ? External switch control for load 1
S2 ? External switch control for load 2
1. Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not shor
damage to the Nano Switch.
Note: Your home?s main circuit breaker must support the overload protection for safety.
2. Preparing connection wires 14 AWG power wires for Input/ Output. 18 AWG copper wires for external manual sw
the connection wire and make sure the length of the metallic part is about 5mm.
Note: All connection wires needs to be flexible cable.
Wiring diagram of AC120V/230V power input.
http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW116
Pagina 3 van 16