If you are using other products as your main Z-Wave controller, please refer to the part of their respective manuals that tells
you how to remove devices from your network.
If you're using an existing gateway:
1. Set your Z-Wave Controller into 'Remove Device' / 'Unpair Device' mode.
Refer to the Controller's manual if you are unsure of how to perform this step.
2. Make sure the product is powered. If not, plug it into a wall socket and power it on.
3. Click Action Button 2 times quickly; it will bright violet light up to 2s.
a. If Removing fails, it will bright red light for 2 seconds and then turn back to Load Indicator Mode; repeat steps 1 to 3.
Contact us for further support if needed.
b. If Removing succeeds, it will become breathing blue light. Smart Switch 7 is removed from the Z-Wave network
successfully and is ready to be paired again.
Reset your Smart Switch 7.
If the primary controller is missing or inoperable, you may need to reset the device to factory settings.
Make sure the product is powered. If not, plug it into a wall socket and power on. To complete the reset process manually:
1. Press and hold the Action Button for at least 20 seconds and then release.
2. The LED indicator will fade its blue light in and out slowly, which indicates the reset operation is successful.
Configurations.
Parameter 4 - Overload threshold.
If power exceeds the value set in this parameter for over 1 minute, Smart Switch 7 will report and overload report and turn off
Smart Switch 7.
Size = 2 Byte
Default Setting = 2415W
Value
Description
Set Watt (W) Threshold for
0 - 2415
Overpower.
Parameter 8 - Switch reaction to alarm.
Set the response of the switch in response to an operation performed when an alarm is received.
Size = 1 Byte
Default Setting = 0
Value
Description
0
No action.
1
Turn switch off
2
Turn switch on
Turn the switch on for 5
seconds, then off for 5
3
seconds until the alarm is
disabled.
Parameter 9 - Alarm reaction when received.
Configure what alarms Smart Switch 7 will react to from other Z-Wave devices.
Size = 2 Byte
Default Setting = 0
Value
Description
The alarm will be triggered
0
by open state, and be
disabled by closed state.
https://aeotec.freshdesk.com/support/solutions/articles/6000219911-smart-switch-7-user-guide-
Smart Switch 7 user guide : Aeotec Group