Ariston EuroCombi Type C 23 MFFI Onderhoudsinstructies - Pagina 3
Blader online of download pdf Onderhoudsinstructies voor {categorie_naam} Ariston EuroCombi Type C 23 MFFI. Ariston EuroCombi Type C 23 MFFI 32 pagina's.
1.
SERVICING
INSTRUCTIONS
1.1
Replacement
of Parts
1.2T
o Gain General
Access
A
B029
Supplied By www.heating spares.co Tel. 0161 620 6677
To ensure efficient safe operation, it is recommended that the boiler is servi-
ced annually by a competent person.
Before starting any servicing work, ensure both the gas and electrical
supplies to the boiler are isolated and the boiler is cool.
Before and after servicing, a combustion analysis should be made via the flue
sampling point (please refer to the Installation Manual for further details).
After servicing, preliminary electrical system checks must be carried out to
ensure electrical safety (i.e. polarity, earth continuity, resistance to earth and
short circuit).
The life of individual components vary and they will need servicing or repla-
cing as and when faults develop.
The fault finding sequence chart in chapter 2 will help to locate which com-
ponent is the cause of any malfunction, and instructions for removal, inspec-
tion and replacement of the individual parts are given in the following pages.
All testing and maintenance operations on the boiler require the control panel
to be lowered. This will also require the removal of the casing.
To dismantle the front part of the casing, proceed as follows:
1. Remove screw "A" (see fig. 1.1);
2. Lift the front panel up and forward (see fig. 1.2).
Fig. 1.1
Fig. 1.2
3