This parameter allows switching between internal sensor and external sensor.
Size: 1 Byte, Default Value: 0
Setting Description
the internal hall sensor is enabled (external
0
input disabled)
the external input is enabled (internal hall
1
sensor disabled)
Parameter 2: Dry Contact Operation Mode
Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact
terminals.
Size: 1 Byte, Default Value: 0
Setting
Description
NO Toggle / Follow state will follow the input of the dry contact terminals where
0
OFF is CLOSED, and ON is OPEN.
NC Toggle / Follow state will follow the input of the dry contact terminals where
1
ON is CLOSED, and OFF is OPEN.
NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF
2
to ON signal.
NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON
3
toOFF signal.
Parameter 3: Door/Window State.
This parameter allows setting Door / Window Sensor 7 state when the magnet is close to the sensor.
Size: 1 Byte, Default Value: 0
Setting Description
0
closed when the magnet is near
1
opened when the magnet is near
Parameter 4: Visual LED Indications.
This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life.
Size: 1 Byte, Default Value: 7, Range: 0 - 7
Setting Description
0
no indications
1
indication of opening/closing status change
indication of wake up (1 x click or
2
periodical)
4
indication of device tampering
Parameter 5: Range test after double click.
Allows enabling the activation of Z-Wave range test with double click of a Tamper Switch 2.
Size: 1 Byte, Default Value: 0
10 z 14
https://aeotec.freshdesk.com/support/solutions/articles/6000230465