Whirlpool 12828188A Gebruiksaanwijzing - Pagina 16

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Whirlpool 12828188A. Whirlpool 12828188A 36 pagina's. Whirlpool refrigerator user instructions

Whirlpool 12828188A Gebruiksaanwijzing
This system has been tested according to NSF/ANSI
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
Asbestos
99%
Live Cysts
>99.95%
Turbidity
0.5 NTU
Lindane
0.0002 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to
71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter's rated life is used, the yellow (Order)
light comes on. When 100% of the filter's rated life is used, the
red (Replace) light comes on, and it is recommended that you
replace the filter. For models without filter status lights,
replace the filter every 6 months. Use replacement filter model
67003523; order Part Number 4396395. 2007 suggested retail
price of $49.99 U.S.A./$65.95 Canada. Prices are subject to
change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the "Water Filtration System" section for the
Manufacturer's name and telephone number.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
††
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
16

PRODUCT DATA SHEETS

Interior Water Filtration System
Model 67003523-750 Capacity 750 Gallons (2839 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,
Mercury, Atrazine, Toxaphene, Cysts, Turbidity, Asbestos and Lindane.
Standards 42 and 53
Average
Influent Challenge
Influent
Concentration
1.88 mg/L
2.0 mg/L ± 10%
5,700,000 #/mL
At least 10,000
particles/mL
Average
Influent Challenge
Influent
Concentration
0.153 mg/L
0.15 mg/L ± 10%
0.150 mg/L
0.15 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.015 mg/L
0.015 ± 10%
0.009mg/L
0.009 mg/L ± 10%
155 MF/L
10
166,500 #/L
50,000/L min.
10.7 NTU
11 ± 1 NTU
0.002 mg/L
0.002 ± 10%
for the reduction of the substances listed below. The
Standards 42 and 53.
Maximum
Effluent
0.06 mg/L
69,000 #/mL
Maximum
Effluent
< 0.001mg/L
< 0.001mg/L
0.0005 mg/L
0.0015 mg/L
< 0.001mg/L
< 0.002 mg/L
7
8
††
to 10
fibers/L
< 1 MF/L
< 1 #/L
0.49 NTU
< 0.0001mg/L
Refer to the "Warranty" section for the Manufacturer's limited

warranty.

Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average
Minimum%
Effluent
Reduction
0.05 mg/L
96.84
**
30,583 #/mL
98.94
Average
Minimum%
Effluent
Reduction
< 0.001mg/L
>99.29%
< 0.001mg/L
>99.29%
0.0003 mg/L
90.91
0.0008 mg/L
75.93
< 0.001mg/L
91.67%
< 0.002 mg/L 75.31%
< 1 MF/L
>99.99%
< 1 #/L
>99.99
0.31 NTU
95.2
0.000 mg/L
96.50%
City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.78 gpm (2.9 L/min.) @ 60 psi
Average%
Reduction
>97.26
99.52
Average%
Reduction
>99.35%
>99.33%
95.70
86.22
92.97%
76.99%
>99.99%
>99.99
97.09
98.72%