10. CONTROL BOARD

WARNING - ELECTRICAL SHOCK
The Control Board Heat Sink will remain charged for five (5) minutes after power is disconnected from the appliance. To
avoid electrical shock DO NOT come in contact with the Control Board until the appliance has been removed from live
current for at least five (5) minutes, and the Heat Sink has had an opportunity to discharge.
• To make the removal of the Control Board easer first remove the Main Motor (see section 9, page 9 for Main Motor removal).
• Next remove the four Phillips board mounting screws and the connector cover (Fig. 10-1).
• Tip the appliance forward and then remove the Capacitor by loosening the 13mm Capacitor Mounting Nut from the bottom of the
unit (Fig. 10-1).
Control Board removal continued on page 11.