Ariston use and booklet Handleiding voor verzorging, gebruik en installatie - Pagina 12

Blader online of download pdf Handleiding voor verzorging, gebruik en installatie voor {categorie_naam} Ariston use and booklet. Ariston use and booklet 15 pagina's. Tumble dryer
Ook voor Ariston use and booklet: Handleiding voor verzorging, gebruik en installatie (40 pagina's), Handleiding voor verzorging, gebruik en installatie (40 pagina's)

Ariston use and  booklet Handleiding voor verzorging, gebruik en installatie
Installation Instructions
Read these instructions with care.
These instructions are provided for us e by qualified installers, in addition the installation must comply with:
In the United States, in accordance with the National Electric Code ANSI/NFPA70 – latest edition and any State,
Municipal or local codes.
In Canada, in accordance with the Canadian Electric Code C22.1 – latest edition and any Provincial, Municipal or
local codes

Electrical

The dryer comes with a three cord power supply cord fitted with a 5-15P (plug), a receptacle should be installed in a
location accessible after the dryer is installed.
Grounding
Some local codes may require a separate ground. In such cases the required ground wire, clamp and screw
must be purchased separately.
NEVER ground the dryer to plastic plumbing lines, gas lines or water pipes.
NOTE: IF IN DOUBT ABOUT ANY OF THE ABOVE
CONSULT A QUALIFIED ELECTRICIAN

Where to put your dryer

Check local codes before choosing a location. Some codes do not permit installation in a garage, c loset, mobile home
or bedroom.. DO NOT install the dryer in an area where gasoline or other flammable materials are kept or stored.
W hen operating the dryer, there has to be adequate ventilation to avoid the back flow of gases into the room from
appliances burning other fuels, including open fires.
Minimum installation clearances.
Sides
Top
Rear
Front
Vent Opening –
Distance from
Top of closet
If installed in a closet it must have the following dimensions and have two ventilation openings each having and area 72
sq. ins. (450 sq. cm) located) 2" (50mm or 6" (150mm) from top[see table] and 6" (150mm) from bottom of door.
It must NEVER be installed in a closet with a solid door.
The dryer has adjus table height feet, use these to level the dryer after fitting into its final position.
RV/Marine Installations
W hen locating the appliance in a towable trailer or watercraft, position the dryer over the axles or mid-ship
where movement is at a minimum. Block the dryer to prevent extreme movement or tipping.
Closet
Closet (alternative)
¾" (15 mm)
½" (10 mm)
4" (100 mm)
¾" (15 mm)
¾" (15 mm)
¾" (15 mm)
¾" (15 mm)
6" (150mm)
2" (50mm)
12
Under Counter
0
¾" (15 mm)
½" (10 mm)
¾" (15 mm)
not applicable
not applicable
TD4089 issue 3