Whirlpool 8578185 Gebruiks- en onderhoudshandleiding - Pagina 5
Blader online of download pdf Gebruiks- en onderhoudshandleiding voor {categorie_naam} Whirlpool 8578185. Whirlpool 8578185 28 pagina's. Electronic electric dryer
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (61 cm) of either side of the dryer.
See "Electrical Requirements."
A sturdy floor to support the total dryer weight of 200 lbs
(90.7 kg). The combined weight of a companion appliance
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. If slope is greater than 1" (2.5 cm), install Extended
Dryer Feet Kit, Part Number 279810. Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at
least 18" (46 cm) above the floor. If using a pedestal, you will
need to place the pedestal at least 6" (22.9 cm) above the
floor.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
Companion appliance spacing should also be considered.
Location Requirements
Dryer Dimensions
38"
(96.52 cm)
*Most installations require a minimum 5½" (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for custom undercounter
installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter installation - Dryer only
0"
(0 cm)
(96.52 cm)
*Additional spacing recommended
Minimum installation spacing for recessed or closet
installation, with or without a pedestal
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Closet installation - Dryer only
(2.5 cm)
*Side or bottom venting - additional spacing recommended
*31½"
(80 cm)
27"
(68.6 cm)
38" min.
0"*
27"
(0 cm)
(68.6 cm)
14" max.
2
48 in.
(35.6 cm)
2
(310 cm
)
18" min.
(45.72 cm)
2
24 in.
2
(155 cm
)
1"
31½"
0"*
(0 cm)
(80 cm)
A
A. Side view - closet or confined area
B. Closet door with vents
51½"
(130.81 cm)
0"*
(0 cm)
3"
(7.6 cm)
3"
(7.6 cm)
B
5