Whirlpool Cabrio WGD8000D Gebruikershandleiding - Pagina 2
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Whirlpool Cabrio WGD8000D. Whirlpool Cabrio WGD8000D 30 pagina's. Smart electronic dryer
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be
½" IPS. When acceptable to the gas supplier and local codes,
lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An
individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code
ANSI Z223.1.
ELECTRICAL REQUIREMENTS - Gas models only
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit
are recommended.
ELECTRICAL REQUIREMENTS - Electric models only
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch circuit.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Acceptable Style:
Angled Hood
Determine vent path:
Select route that will provide straightest and most direct
■
path outdoors.
Plan installation to use fewest number of elbows and
■
turns.
When using elbows or making turns, allow as much
■
room as possible.
Bend vent gradually to avoid kinking.
■
Use as few 90° turns as possible.
■
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Box Hood
⁄
" approved tubing may be used for lengths under 20 ft (6.1 m). For
3
8
Determine vent length and elbows needed for best
drying performance:
Use following Vent System Chart to determine type of vent
■
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
Shorten life of dryer.
■
Reduce performance, resulting in longer drying times
■
and increased energy usage.
The Vent System Charts provide venting requirements that
will help achieve best drying performance.
Vent System Chart
Number of
90° elbows
0
1
2
3
4
NOTE: Bottom exhaust installations have a 90° turn inside the
dryer. To determine maximum exhaust length, add one 90° turn
to the charts.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Type of vent
Angled
hoods
Rigid metal
64 ft. (20 m)
Rigid metal
54 ft. (16.5 m)
Rigid metal
44 ft. (13.4 m)
Rigid metal
35 ft. (10.7 m)
27 ft. (8.2 m)
Rigid metal