Whirlpool Duet sport YWED8410SW2 Gebruiks- en onderhoudshandleiding - Pagina 19

Blader online of download pdf Gebruiks- en onderhoudshandleiding voor {categorie_naam} Whirlpool Duet sport YWED8410SW2. Whirlpool Duet sport YWED8410SW2 44 pagina's. Electronic electric dryer

Is a coin, button, or paper clip caught between the drum
and front or rear of the dryer?
Check the front and rear edges of the drum for small objects.
Clean out pockets before laundering.
Are the four legs installed, and is the dryer level front to
back and side to side?
The dryer may vibrate if not properly installed. See
"Installation
Instructions."
Is the clothing knotted or balled up?
When balled up, the load will bounce, causing the dryer to
vibrate. Separate the load items and restart the dryer.
Dryer displaying
code message
"PF" (power failure), check the following:
Was the drying cycle interrupted
by a power failure?
Press and hold START to restart the dryer.
"F-" Variable
(F-01, F-22, F-23, F-26) service
codes (the
display alternately
flashes
"F-" and then the error code
number):
Call for service.
Clothes are not drying satisfactorily, drying times are too
long, or load is too hot
Is the lint screen clogged with lint?
Lintscreen should be cleaned before each load.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow
these instructions can result in death
or fire.
Is the exhaust vent or outside exhaust hood clogged with
lint, restricting air movement?
Run the dryer for 5-10 minutes. Hold your hand under the
outside exhaust hood to check air movement.
If you do not
feel air movement, clean exhaust system of lint or replace
exhaust vent with heavy metal or flexible metal vent. See
"Venting Requirements."
Are fabric softener sheets blocking the grille?
Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length?
Check that the exhaust vent is not too long or has too many
turns. Long venting will increase drying times. See "Plan Vent
System."
Is the exhaust vent diameter the correct size?
Use 4" (10.2 cm) diameter vent material.
Explosion
Hazard
Keep flammable
materials
and vapors,
such as
gasoline,
away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
Is the dryer located in a room with temperature
below
45°F (7°0)?
Proper operation of dryer cycles requires temperatures
above
45°F (7°C).
Is the dryer located in a closet?
Closet doors must have ventilation openings at the top and
bottom of the door. The front of the dryer requires a minimum
of 1" (2.5 cm) of airspace, and, for most installations, the rear
of the dryer requires 5" (12.7 cm). See "Installation
Instructions."
Has the Air Only modifier
been selected?
Select the right temperature for the types of garments being
dried. See "Additional Features."
Is the load too large and heavy to dry quickly?
Separate the load to tumble freely.
Cycle time too short
Excessive
Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
Is the automatic
cycle ending early?
The load may not be contacting the sensor strips. Level the
dryer.
Change the dryness level setting on Auto Cycles. Increasing
or decreasing the dryness level will change the amount of
drying time in a cycle.
Do not use a dryer rack with an Auto Cycle.
Lint on load
Is the lint screen clogged?
Clean lint screen. Check for air movement.
Stains on load or drum
Was dryer fabric softener properly used?
Add dryer fabric softener sheets at the beginning of the cycle.
Fabric softener sheets added to a partially dried load can
stain your garments.
Drum stains are caused by dyes in clothing (usually blue
jeans). This will not transfer to other clothing.
19