Whirlpool WGD97HEXW0 Handleiding voor installatie-instructies - Pagina 6

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Whirlpool WGD97HEXW0. Whirlpool WGD97HEXW0 38 pagina's. Gas dryer
Ook voor Whirlpool WGD97HEXW0: Gebruiks- en onderhoudshandleiding (36 pagina's)

Whirlpool WGD97HEXW0 Handleiding voor installatie-instructies
IMPORTANT:
Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures
below
45 ° F (7° C). Lower temperatures
may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
Installation spacing
for recessed
area
or closet installation
All dimensions show recommended spacing allowed, with
tested spacing of 0" (0 mm) clearance on sides and rear.
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door,
and floor moldings.
[] Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation
openings are
acceptable.
[] Companion appliance spacing should also be considered.
Closet installation {dryer only}:
5 mm
i (_
34" rain.
(864ram)
(763mm)
3"
(76 ram)
t
48 in.2
(310 cm 2)
24 in.2
(155 cm 2)
ELECTRIC
DR R
FOWER
HOOKUFo
ONLY
ELECTRICAL
REQUIREMENTS
E(ectrical
Shock Hazard
Plug into a grounded 4 prong out(et,
Failure to do so can result in death or electrical
shock.
it is your
responsibility:
[] To contact a qualified electrical installer.
[] To be sure that the electrical connection is adequate and in
conformance
with Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
[] To supply the required 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended.
Connect to an individual branch
circuit.
[]
This dryer is equipped with a CSA
international
Certified Power Cord
intended to be plugged into a standard
14-30R wall receptacle. The cord is 5 ft.
(1.52 m) long. Be sure wall receptacle is
within reach of dryer's final location.
4-wire receptacle
(14-30R)
If using a replacement
power supply cord, it is recommended
that
you use Power Supply Cord Replacement
Part Number 9831317.
For further information, please reference service numbers located
in "Assistance
or Service" section of your Use and Care Guide.
Mobile
home
= Additional
installation
requirements:
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile home construction
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240
MH.
Mobile
home
installations
require:
[] Metal exhaust system hardware, available for purchase from
your dealer. For further information, see "Assistance
or
Service" section in your Use and Care Guide.
[] Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a nearby
window) should be at least twice as large as dryer exhaust
opening.
For mobile home installation of gas dryers:
[] Mobile Home installation Hold-down
Kit Part Number 346764
is available to order. For further information, see
"Assistance or Service" section in your Use and Care Guide.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding
conductor and a grounding
plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
improper connection of the equipment-
grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
6