Whirlpool YWED9500E Handleiding voor installatie-instructies - Pagina 13

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Whirlpool YWED9500E. Whirlpool YWED9500E 26 pagina's. Gas and electric dryer

Whirlpool YWED9500E Handleiding voor installatie-instructies
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads.
2.
Attach direct wire cable
to strain relief
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
If your wiring looks like this:
4-wire direct connection:
Go to "4-Wire Direct Connection"
on this page.
3-wire direct connection:
Go to "3-Wire Direct Connection"
on page 11.
4-wire Direct Wire Connection
IMPORTANT:
A 4-wire connection is required for mobile
homes and where local codes do not permit 3-wire
connections.
1.
Prepare your 4-wire cable for
direct connection
Direct wire cable must have 5 ft. (1.52 m) of extra length
so dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 1
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
2.
E
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
3.
Connect neutral ground wire (E) and place
hooked end (hook facing right) of neutral
wire (white or center wire) (C) of direct wire
cable under center screw of terminal block
(B). Squeeze hooked ends together and
tighten screw.
4.
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
/
" (38 mm)
1
2
Prepare to connect neutral
ground wire and neutral wire
Connect neutral ground wire
and neutral wire
C
Connect ground wire
B
A
E
B
F
A
13