B
A. Keyhole slots (4)
B. Mounting screw
1. Install 2 PAR20, 50W maximum halogen bulbs or 2 R16, 40W
maximum incandescent bulbs. Bulbs are purchased
separately.
2. Replace filters
NOTE: Filter slot must be toward front of range hood.
Hood control panel
A
A. Fan switch
B. Light switch
Operating the fan
A 3-position rocker switch controls the fan. The left position is
low speed, center position is off, and the right position is high
speed. An indicator light shows the fan is on.
Be sure lights are cool before cleaning the range hood.
To clean range hood
1. Disconnect power.
2. Remove filters.
3. Use a damp cloth and a mild detergent to wipe all grease-
laden surfaces. During cleaning of fan blade, do not allow it to
become bent or misaligned.
4. Do not allow water to enter the motor.
5. Make sure all surfaces are completely dry before replacing
filters.
6. Reconnect power.
Motor is permanently lubricated. Do not oil or disassemble motor.
10
A
A
Complete Installation
RANGE HOOD USE
B
RANGE HOOD CARE
Cleaning and Maintenance
4. Tighten mounting screws to cabinet, making sure mounting
screws are in narrow neck of slots.
For vented installations:
1. Make sure that damper blade opens and closes freely.
2. Connect ventwork to range hood. Seal joints with vent
clamps to make them secure and air tight.
For non-vented installations: Attach the charcoal filters (not
supplied) to the aluminum filters with the special blue and
yellow strips facing toward the cooking surface. Make sure
fan blade turns freely.
3. Reconnect power.
4. Check for proper operation.
Operation
Operating the light
A 3-position rocker switch controls the lights. The left position is
low light intensity, center position is off, and the right position
high light intensity.
Replacing the bulbs
Before you begin, make sure that the range hood is turned off
and that the lamps have had sufficient time to cool. Halogen
bulbs burn extremely hot. See bulb packaging for further
information.
Replace with 2 PAR20, 50W maximum halogen bulbs or 2 R16,
40W maximum incandescent bulbs.
Aluminum mesh filters
Clean often using hot water and a mild detergent. Filters are
dishwasher safe.
Charcoal filters (non-vented installations)
Clean filter surfaces frequently with a damp cloth and mild
detergent. Do not immerse filters in water or put in
dishwasher.
Special blue and yellow strips will blend to green when it is
time to change the filter. These strips work best when facing
toward the cooking surface.
30" (76.2 cm) filter kit Number 4396291 or 36" (91.4 cm) filter
kit Number 4396292 is available from your dealer.