Whirlpool GZ5736XR Series Installatie-instructies en gebruiks- en onderhoudshandleiding
7" (17.8 cm) Vent System
Vent Piece
45° elbow
90° elbow
7" (17.8 cm)
wall cap
3 " x 10" (8.3 cm x 25.4 cm)
to 7" (17.8 cm)
3 " x 10" (8.3 cm x 25.4 cm)
to 7" (17.8 cm) 90° elbow
Example vent system
90˚ elbow
2 ft (0.6 m)
Maximum Recommended Length
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of 7" (17.8 cm) system
6
7" (17.8 cm) Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 50 ft (15.2 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)

INSTALLATION INSTRUCTIONS

Prepare Location

1. If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to upper
cabinet or rear wall. Slide cardboard or hardboard under
range before moving range across floor to avoid damaging
floor covering. Otherwise, put a thick covering over
countertop, cooktop or range to avoid damage or dirt.
2. Determine which venting method (roof, wall or non-venting)
you need to use. This range hood is shipped for non-vented
installation.
A
centerline
cabinet
bottom
wall
" (3.0 mm)
pilot holes
Hood size
30" (76.2 cm)
13
36" (91.4 cm)
16
3. Drill four
" (3.0 mm) pilot holes for hood mounting screws. If
cabinet has recessed bottom, add wood shim strips on each
side.
4. From the following diagrams, select the diagram for your
installation.
Vented installations: Cut the vent system and electrical wiring
access holes as required.
If wiring through the top, use location shown in vertical
vent system.
If wiring through the back, use location shown in
horizontal vent system.
3 " x 10" (8.3 x 25.4 cm) rectangular vertical vent system
5 "
(13.3 cm)
centerline
wall
5"
1 "
(12.7 cm)
(3.2 cm)
10 "
A
(26.7 cm)
wood shim strips
(recessed cabinet
bottoms only)
1 "
(3.8 cm)
A
" (35.4 cm)
" (43.0 cm)
7 "
(19.1 cm)
1 " (3.2 cm)
2"
dia. hole