Whirlpool GZ7730XGS1 Installatie-instructies en gebruiks- en onderhoudshandleiding - Pagina 5

Blader online of download pdf Installatie-instructies en gebruiks- en onderhoudshandleiding voor {categorie_naam} Whirlpool GZ7730XGS1. Whirlpool GZ7730XGS1 36 pagina's. 30" (76.2 cm) and 36" (91.4 cm) slide-out vent range hood
Ook voor Whirlpool GZ7730XGS1: Onderdelenlijst (4 pagina's)

Product Dimensions
30" (75.2 cm) model: 8" (20.3 cm)
36" (01.4 cm) model: 11" (27.9 cm)
FRONT OF
VENT HOOD
30" (76.2 cm) model: 25" (66_.0 cm)
35" (91.4 cm) modem: 32" (81.3 cm)
10"
91/2 ''
(24.1 cm)
Shelf extends
(20.3 cm)
7" (17.,0 cm)\
/ /
\
1%"
1"
nm)
(31.8 mm)
%" to 2%"
1.6 cm
91/8 "
11"
(23.2
cm)
(27.9 era)
\
\
%" (9.5 ram)
30" (75.2 cm) model:
13" (33.0 cm)
136"
(91.4 cm) model:
15" (40.6 cm)
BACK OF
VENT HOOD
J
J
30" (76.2 era) model:
297/8 '' (75.9 cm)
36" (91.4cm) model: 357/8 ' ' (91.1 cm)
Installation Clearances
30" (76.2 cm)
suggested max.
bottom
of cabinet
to cooking
surface
.....
I.....
30" (76.2 cm) or
36" (91.4 cm) min.
cabinet
opening
width
/
24" (61 cm)
rain.
13"
(33 cm)
cabinet
depth
15" (38.1
cm)
min.
clearance-
upper cabinet
_
to countertop
__
/
36" (91.4era)
base cabinet
height
66"(167.8
cm)
/
rain.
72" (182.9
cm)
max.
to bottom of
cabinet frame
Vent system must terminate to the outside, except for non-
vented (recirculating) installations,
Do not terminate the vent system in an attic or other enclosed
area,
Do not use a 4" (10.2 cm) laundry-type
wall caps,
Use a metal vent only, A rigid metal vent is recommended,
Do
not use plastic or metal foil vent.
The size of the vent should be uniform.
Use no more than three 90 ° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than one elbow is used,
Do not install 2 elbows together.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance,
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
Determine which venting method is best for your application.
Cold weather
installations
An additional back draft damper should be installed to minimize
backward cold air flow and a nonmetallic thermal break should
be installed to minimize conduction of outside temperatures
as
part of the vent system. The damper should be on the cold air
side of the thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.