Whirlpool UTX5536AAB0 Installatie-instructies en gebruiks- en onderhoudshandleiding - Pagina 4

Blader online of download pdf Installatie-instructies en gebruiks- en onderhoudshandleiding voor {categorie_naam} Whirlpool UTX5536AAB0. Whirlpool UTX5536AAB0 28 pagina's. 30" (76.2 cm) and 36" (91.4 cm) range hood installation instructions

INSTALLATION REQUIREMENTS
s c nd
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Drill
lY4" (3.0 cm) drill bit
1/8"(3.0 mm) drill bit for pilot holes
Pencil
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof
caulking compound
Flat-blade screwdriver
Phillips screwdriver
For vented installations, you also need:
Saber or keyhole saw
Vent clamps
Metal snips
Compass or 8" (20.3 cm) circle template
Parts supplied
Remove parts from package. Check that all parts are included.
2- Metal filters
6 - 4.5 x 13 mm mounting screws
3- 4 x 8 mm damper screws
31/4"x 10" (8.3 x 25.4 cm) damper/vent
connector
4-5x45mmscrews
4- 8 x 40 mm wall anchors
Recirculating kit
Charcoal filters for non-vented (recirculating) installations. See
the "Assistance or Service" section to order replacement
filters.
Parts needed
For vented installations:
31/4"X 10" (8.3 X 25.4 cm) or 6" (15.2 cm) or larger round metal
venting
6" (15.2 cm) or larger round damper, if using 6" (15.2 cm) or
larger round vent system
31/4 '' x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter
transition piece if using 6" (15.2 cm) or larger diameter round
vent system.
For cabinets with recessed bottoms:
Two 2" (5.1 cm) wide filler strips. Length and thickness
determined by recess dimensions.
Four flat head wood screws or machine screws with washers
and nuts (to attach filler strips).
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility
to comply with installation
clearances specified on the model/serial rating plate. The
model/serial
rating plate is located inside the range hood on
the left wall.
Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range
manufacturer
installation instructions
before
making any cutouts.
Grounded electrical outlet is required. See "Electrical
Requirements"
section.
The hood is factory-set
for vented installations.
For non-
vented (recirculating) installations, the Recirculation
Kit is
included. See the "Assistance
or Service" section to order
Replacement
Charcoal Filters Part Number W10272068.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities
and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
13/16"
(3.0 crn)
12"
(30.5 cm
3" (7.6 cm) =
30" (76.2cm) modem
2"
(5.1cm)
5 3/4" (14.6crn) -
36"
(91.4 cm)
modem
9"
(22.9 crn)
29 %" (75.9cm)- 30"_6.2 cm)
(50.2cm)
35 %" (91.1cm)- 36"(91.4cm)mo_