Whirlpool UXT2030ADB Installatie-instructies en gebruiks- en onderhoudshandleiding - Pagina 6
Blader online of download pdf Installatie-instructies en gebruiks- en onderhoudshandleiding voor {categorie_naam} Whirlpool UXT2030ADB. Whirlpool UXT2030ADB 32 pagina's. 30" (76.2 cm) range hood
Ook voor Whirlpool UXT2030ADB: Installatie-instructies en gebruiks- en onderhoudshandleiding (28 pagina's)
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent System
Vent Piece
45° elbow
90° elbow
7" (17.8 cm) wall cap
Example vent system
90˚ elbow
2 ft (0.6 m)
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
System length
Maximum Recommended Length
7" (17.8 cm) Round Vent
6
2.5 ft (0.8 m)
5 ft (1.5 m)
0 ft (0 m)
Wall cap
6 ft (1.8 m)
= 5 ft (1.5 m)
= 0 ft (0 m)
= 8 ft (2.4 m)
= 13 ft (3.9 m)
= 50 ft (15.2 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (latest edition) or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition),
and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 V, 60 Hz, AC only, 15 A, fused
■
electrical circuit is required.
If the house has aluminum wiring, follow
■
the procedure below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform
with local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating
■
of the appliance as specified on the model/serial/rating
plate. The model/serial/rating plate is located inside the
range hood on the left wall.
Wire sizes must conform to the requirements of the National
■
Electrical Code, ANSI/NFPA 70 (latest edition) or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 (latest edition), and all local codes
and ordinances.