Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Metal snips
#2 Phillips
screwdriver
Pencil
Caulking gun and weatherproof
caulking compound
Jigsaw or keyhole saw
Parts supplied
Remove parts from package. Check that all parts are included.
#8-18 x 1"
(4.2 x 25 mm)
flat-head screws
Drywall
anchors
Short Phillips
head screws

INSTALLATION REQUIREMENTS

Wire stripper
Flat-blade
screwdriver
Drill with ¹⁄₈"
(3 mm), ¹⁄₂"
(13 mm)
and 1¹⁄₄"
(3 cm) bits
#8-18 x ⁵⁄₈"
(4.2 x 16 mm)
truss-head screws
Mounting
brackets
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
rectangular
damper
Parts needed
UL Listed/CSA
UL Listed/CSA
Approved ¹⁄₂" (13 mm)
Approved
strain relief
wire connectors
For 7" (17.8 cm) round vented installations
7" (17.8 cm)
round
metal vent
system with
wall or roof cap
Vent clamps as
required
For 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vented installations
3¹⁄₄" x 10"
(8.3 x 25.4 cm) rectangular
metal vent system with
wall or roof cap
Optional accessories
Power
Charcoal
cord kit
filter kit
Part Number
Part Number
W10355452*
W10355450*
*For information on ordering, see the "Assistance or Service"
section.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located inside the range hood on
the left wall.
Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.
This range hood is recommended for use with cooktops with
a maximum total rating of 40,000 Btus or less.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
All openings in ceiling and wall where range hood will be
installed must be sealed.
These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters. See the "Assistance or
Service" section for information on ordering charcoal filters.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
120V, 75W
maximum,
type E26
incandescent lamp
7" (17.8 cm)
round damper
Part Number
W10355451*
7" (17.8 cm)
round vent
mounting plate
Part Number
W10388168*
Duct tape
Stainless steel
cleaner and
polish
Part Number
31462A*